Technical product information Transaction No.: 2023803/1
A3 with S-Tronic (0AM) - 30A Mechatronic fuse incorrect, entry P0562 Release date: 26-Jul-2010 Customer statement / workshop findings Various running problems in connection with the following entries. • P0562 / 21148 – supply voltage of motor too low • P189C / 21247 – pressure accumulator diagnosis not possible Technical background Because of incorrect Mechatronics components the 30A fuse (SB-2) in the fuse holder B can blow, disrupting the power supply of the Mechatronics. Production change - - - Measure Try to reproduce the customer complaint so that it can be clearly assigned to this TPI. The following repair must only be carried out, if all the criteria (model/type, chassis number, engine/gearbox code, PR number(s), software version, code etc. ) match exactly. Otherwise this solution won't work and repeat repairs may be necessary. In such a case, we may reject the warranty claim and redebit the parts. 1. Check the fuse SB-2 (30A.) for the Mechatronics power supply (J743) according to the current flow diagram. If the fuse is incorrect, replace it. 2. Check the system again. If the complaint is fixed, replace the Mechatronics according to the repair manual. Warranty accounting instructions Service number/damage code: 3511 / 0015 Accounting with APOS Repair operation: Designation: Time units: 35110199 Check Mechatronics 20 35111903 Remove and install Mechatronics 250 01500000 GFF/guided functions TU according to diagnosis protocol The labour times are correct at the time of publication. Accounting with APOS/2 Illustration: Position: Number: Designation: Activity: Time units: 321-62 1 325 025 Mechatronics 02 20 321-62 1 325 025 Mechatronics 55 Time from APOS2 STA-02 1 S00032 Guided fault finding 02 TU according to diagnosis protocol The labour times are correct at the time of publication. |
![]() |
![]() |
Сказал Спасибо bat_svilen за это сообщение: | FeelGood (24.10.2013) |
![]() |
|
|