Technical product information Transaction No.: 2023803/1
A3 with S-Tronic (0AM) - 30A Mechatronic fuse incorrect, entry P0562 Release date: 26-Jul-2010

Customer statement / workshop findings

Various running problems in connection with the following entries.

• P0562 / 21148 – supply voltage of motor too low

• P189C / 21247 – pressure accumulator diagnosis not possible


Technical background

Because of incorrect Mechatronics components the 30A fuse (SB-2) in the fuse holder B can blow, disrupting the power supply of the Mechatronics.

Production change

- - -

Measure

Try to reproduce the customer complaint so that it can be clearly assigned to this TPI.

The following repair must only be carried out, if all the criteria (model/type, chassis number, engine/gearbox code, PR number(s), software version, code etc. ) match exactly. Otherwise this solution won't work and repeat repairs may be necessary. In such a case, we may reject the warranty claim and redebit the parts.

1. Check the fuse SB-2 (30A.) for the Mechatronics power supply (J743) according to the current flow diagram. If the fuse is incorrect, replace it.

2. Check the system again. If the complaint is fixed, replace the Mechatronics according to the repair manual.

Warranty accounting instructions

Service number/damage code: 3511 / 0015


Accounting with APOS

Repair operation:
Designation:
Time units:

35110199
Check Mechatronics
20

35111903
Remove and install Mechatronics
250

01500000
GFF/guided functions
TU according to diagnosis protocol

The labour times are correct at the time of publication.



Accounting with APOS/2

Illustration:
Position:
Number:
Designation:
Activity:
Time units:

321-62
1
325 025
Mechatronics
02
20

321-62
1
325 025
Mechatronics
55
Time from APOS2

STA-02
1
S00032
Guided fault finding
02
TU according to diagnosis protocol

The labour times are correct at the time of publication.