Technical product information Transaction No.: 2022982/3
A3 with S-Tronic (0AM) - gear indicator flashes Release date: 07-Sep-2010 Customer statement / workshop findings Customer complaint: The gear display in the dash insert flashes The following entry can be logged: • P0841 02115x - sender 1 for hydraulic pressure gearbox, implausible signal • If other entries are logged, this TPI does not apply. Technical background The entry is only logged, if the hydraulic pressure in the Mechatronics drops under a certain pressure level. Production change Measure Try to reproduce the customer complaint so that it can be clearly assigned to this TPI. The following repair must only be carried out, if all the criteria (model/type, chassis number, engine/gearbox code, PR number(s), software version, code etc. ) match exactly. Otherwise this solution won't work and repeat repairs may be necessary. In such a case, we may reject the warranty claim and redebit the parts. Update the software of the gearbox control unit with SVM 02A003. Follow this up with an adaptation drive according to the repair manual. Warranty accounting instructions Service number/damage code/manufacturer: 3730 / 0039 Accounting with APOS: Repair operation: Designation: Time units: 27068950 Charge battery 10 TU 34350199 Check gearbox (adaptation drive) 30 TU 01500000 GFF/guided functions TU according to diagnosis protocol The labour times are correct at the time of publication. Accounting with APOS/2: Illustration: Position: Number: Designation: Activity: Time units: STA-02 4 915105 Battery 90 10 TU 300-XX 1 300XXX Check gearbox (adaptation drive) 02 30 TU STA-02 1 S00032 Guided fault finding 02 TU according to diagnosis protocol The labour times are correct at the time of publication. |
![]() |
![]() |
Сказал Спасибо bat_svilen за это сообщение: | FeelGood (24.10.2013) |
|
|