Цитата:
Сообщение от dhardi
Всем привет. Помогите, пожалуйста, найти описание кодов ошибок на still EXV14
----------
частая ошибка L300
|
Потенциометр подьм/опускание вышел за пределы 5 или 95%
L 300
Error on the mast lifting/lowering potentiometer:
"If bits 0 and 2 or bits 1 and 3 are displayed at same time the cause may be a harness error.
"
"If only one bit (0, 1, 2 or 3) is displayed the cause may be located in the command organ. "
"If bits 4 or 5 are displayed the problem may be the potentiometer itself."
Bit 0: mast lifting/lowering command 1 signal too low - X1:12 < 5,0%, 200msec
Bit 1: mast lifting/lowering command 1 signal too high - X1:12 > 95,0%, 200msec
Bit 2: mast lifting/lowering command 2 signal too low - X1:12 < 5,0%, 200msec
Bit 3: mast lifting/lowering command 2 signal too highX1:12 > 95,0%, 200msec
Bit 4: summation of mast lifting/lowering command - X1:12 + X1:26 < 95,0%, 200msec
Bit 5: summation of mast lifting/lowering command - X1:12 + X1:26 > 105,0%, 200msec
Add 2: voltage at X1:12 [o/oo]
Add 3: voltage at X1:26 [o/oo]
Add 4: voltage at X1:12 [cV]
Add 5: voltage at X1:26 [cV]
----------
Цитата:
Сообщение от sirkosobaka222
Приветствую, кто может скинуть электрическую схему на Still R70-30? Буду благодарен. Двигатель работает, не едет ни вперед, ни назад.
|
Нужно больше информации - год выпуска/серийный номер/объем двигателя.
Много модификаций у этой модели.
Пройдитесь по датчикам безопасности- сиденье,переключатель направления,дверцы и тд.