АСС (адаптивный круиз-контроль) перестало все работать


VCDS недостатки


Address 8B: Adaptive Cruise Control 2 Labels: SVO \ 4H0-907-561.clb
Control unit order number: 7P6 907 541 A HW: 7P6 907 541
System and / or version: ACC3 H13 0230
Coding: 3F04010101
Workshop number: WSC 31414 790 00001
ASAM Dataset: EV_AdaptCruisContr2VW526 001004 (VW52)
ROD: EV_AdaptCruisContr2VW526_001.rod
VCID: 387F9EE183538C8A2D-806C
The faults have been deleted

3 defects found.
17664 - Control unit defective
B2000 00 - -
[Extended UDS fault details are supported only by the current generation of interfaces (HEX-V2 and HEX-NET)]
Confirmed - Tested since clearing memory
fault information:
Status of faults: 00000001
Fault Priority: 1
Frequency of defects: 1

Control unit temperature: 33 ° C
Terminal voltage 15: 9.902 V
Velocity_vehicle_reference: 0 m / s
Longitudinal_acceleration_vehicle_reference: 0.00 m / s²

18176 - Control unit defective
B2000 00 - -
[Extended UDS fault details are supported only by the current generation of interfaces (HEX-V2 and HEX-NET)]
Confirmed - Tested since clearing memory
fault information:
Status of faults: 00000001
Fault Priority: 1
Frequency of defects: 1

Control unit temperature: 33 ° C
Terminal voltage 15: 9.902 V
Velocity_vehicle_reference: 0 m /
Longitudinal_acceleration_vehicle_reference: 0.00 m / s²

18688 - Control unit defective
B2000 00 - -
[Extended UDS fault details are supported only by the current generation of interfaces (HEX-V2 and HEX-NET)]
Confirmed - Tested since clearing memory
fault information:
Status of faults: 00000001
Fault Priority: 1
Frequency of defects: 1

Control unit temperature: 33 ° C
Terminal voltage 15: 9.902 V
Velocity_vehicle_reference: 0 m / s
Longitudinal_acceleration_vehicle_reference: 0.00 m / s²


Address 13: Distance control Labels: SVO \ 4H0-907-561.clb
Control unit order number: 7P6 907 561 A HW: 7P6 907 561
System and / or version: ACC3 H17 0230
Coding: 3F04010101
Workshop number: WSC 22021 401 86144
ASAM Dataset: EV_AdaptCruisContrVW526 001004 (VW52)
ROD: EV_AdaptCruisContrVW526_001.rod
VCID: 3A7B84E9BD5F9E9ADB-806E
The faults have been deleted

1 error found:
92416 - Function restriction received by error value
U1113 00 - 00
[Extended UDS fault details are supported only by the current generation of interfaces (HEX-V2 and HEX-NET)]
Confirmed - Tested since clearing memory
fault information:
Status of faults: 00000001
Fault priority: 6
Frequency of defects: 1
Reset counter: 235
Mileage: 359600 km
Date: 2019.08.24
Time: 16:23:03

Control unit temperature: 28 ° C
Terminal voltage 15: 11.970 V
Velocity_vehicle_reference: -0.01 m / sec
Longitudinal_acceleration_vehicle_reference: 0.00 m / s²


Для просмотра ссылок или изображений в данном разделе, у Вас должно быть не менее 15 сообщение(ий). Сейчас у Вас 0 сообщение(ий).







спасибо за любой совет
Ahoj. Mash v perdeli jednotku slave acc.
Zmenit, nebo fleshovat....
Lixodey вне форума   Ответить с цитированием
Сказал Спасибо Lixodey за это сообщение:
mattock (03.01.2020)