Помогите разобраться, не могу заставить работать VAS5054. После установки ODIS (OE или OS) запускаю PDU-API Test Applicatoin (версии 1.20.20, 1.20.23, 1.20.37, 1.20.42, менял в pdu_api root.xml)
Выбираю (например) EDIC_D_PDU_API_OE нажимаю Parse MDF File, появляется Module VAS5054 Softing AG 082145725, нажимаю PDUModuleConect и зависает. Лог:
Цитата:
************ Getting MVCI Module paths *************
Root description file contains 2 MVCI modules.
*********** Changing the PDU-API module ************
----------------------------------------------------
Selected MVCI module: EDIC_D_PDU_API_OE
----------------------------------------------------
PDU-API dll:
C:\Program Files\Softing\D-PDU API\1.20.020\vecom\PDUAPI_SoftingAG_1.20.020.dll
PDU-API ModuleDescriptionFile:
C:\Program Files\Softing\D-PDU API\1.20.020\vecom\MDF_SoftingAG_EDIC-PDU-API_1.20.020.xml
PDU-API CableDescriptionFile:
C:\Program Files\Softing\D-PDU API\1.20.020\vecom\CDF_SoftingAG_EDIC-PDU-API_1.20.020.xml
Loading PDU-API library file...
PduApiLibPath:"C:\Program Files\Softing\D-PDU API\1.20.020\vecom\PDUAPI_SoftingAG_1.20.020.dll"
Loading successful!
----------------------------------------------------
Parsing MDF file...
MDF parser initialisation successful, MDF file loaded!
MDF parsing completed!
Fixing references completed!
Warning: ComParam ID=4, value Overflow (Max or Min value is set) !
Warning: ComParam ID=5, value Overflow (Max or Min value is set) !
Warning: ComParam ID=6, value Overflow (Max or Min value is set) !
Warning: ComParam ID=7, value Overflow (Max or Min value is set) !
Warning: ComParam ID=38, value Overflow (Max or Min value is set) !
Warning: ComParam ID=39, value Overflow (Max or Min value is set) !
Warning: ComParam ID=40, value Overflow (Max or Min value is set) !
Warning: ComParam ID=132, value Overflow (Max or Min value is set) !
Warning: ComParam ID=134, value Overflow (Max or Min value is set) !
----------------------------------------------------
Parsing CDF file...
CDF parser initialisation successful, CDF file loaded!
CDF parsing completed!
----------------------------------------------------
Return of PDUConstruct:
PDU_STATUS_NOERROR: PDU function call successful
----------------------------------------------------
Return of PDUGetModuleIds:
PDU_STATUS_NOERROR: PDU function call successful
----------------------------------------------------
Number of modules found: 1
hMod: 1, ModuleStatus: PDU_MODST_AVAIL,
Module Type ID: 531,
Vendor Module Name: VendorName='Softing AG' ModuleName='VAS5054' SerialNumber='082145725',
Vendor Additional Info:
|
После того, как выдергиваешь шнур, отвисает и дополнительно появляются строки:
Цитата:
----------------------------------------------------
Return of PDUModuleConnect:
PDU_ERR_FCT_FAILED: PDU function call failed
-------------------------------------------------------
Received an system event item from the PDU-API:
ItemType = PDU_IT_INFO
InfoCode = PDU_INFO_MODULE_LIST_CHG
----------------------------------------------------
Return of PDUGetModuleIds:
PDU_STATUS_NOERROR: PDU function call successful
|