FMI values:
0 = Data Valid but Above Normal Operational Range, Most Severe Level
1 = Data Valid but Below Normal Operational Range, Most Severe Level
2 = Data Erratic, Intermittent or Incorrect (rationality)
3 = Voltage Above Normal, or Shorted to High Source
4 = Voltage Below Normal, or Shorted to High Source
5 = Current Below Normal, or Open Circuit
6 = Current Above Normal, or Grounded Circuit
7 = Mechanical System not Responding or Out of Adjustment
8 = Abnormal Frequency or Pulse Width or Period
9 = Abnormal Update Rate
10 = Abnormal Rate of Change
11 = Failure Code not Identifiable
12 = Bad Intelligent Device or Component
13 = Out of Calibration
14 = Special Instructions
15 = Data Valid but Above Normal Range : Least Severe Level
16 = Data Valid but Above Normal Range: Moderately Severe Level
17 = Data Valid but Below Normal Range: Least Severe Level
18 = Data Valid but Below Normal Range: Moderately Severe Level
19 = Received Network Data in Error: (Multiplexed Data)
20 = Data Drifted High (rationality high)
21 = Data Drifted Low (rationality low)
22 to 30 = Reserved for SAE Assignment
31 = Condition Exists
|