Вот логи.

Saturday,05,July,2014,10:38:11:10463
ВАСЯ -- Windows эмулятор VAG/VAS
ВАСЯ Версия: 12.12.0.0
Версия данных: 20140226


VIN: WVWZZZ16ZCM099337 Номерной знак: 1



--------------------------------------------------------------------------------
--------------------------------------------------------------------------------


Адрес 08: Электроника кондиционера / отопителя (7N0 907 426 AN)

10:37:58
001 Air distribution flap; actual value 80
002 Air distribution flap; defrost stop (via defog) 22
003 Air distribution flap; defrost stop (via upper body outlet) 291
004 Air distribution flap; specified value 21.5 %
005 Air-conditioning operation information not active
006 Blower status On
007 Compressor current; specified value 0.000 A
008 Compressor load 0.0 Nm
009 Compressor shut-off condition; last Shut-off from Engine Control Module (ECM) via CAN
010 Compressor shut-off requirement Shut-off from Engine Control Module (ECM) via CAN
011 Compressor shut-off requirement; antepenultimate Shut-off from Engine Control Module (ECM) via CAN
012 Compressor shut-off requirement; penultimate Shut-off from Engine Control Module (ECM) via CAN
013 Compressor speed 0 /min
014 Convertible top status closed
015 Coolant fan activation; actual value-MUX Lueftersteuerung 9.6 %
016 Coolant fan activation; specified value 0.0 %
017 Coolant temperature 42 °C
018 Counter of compressor switch-offs-Shut-off from Engine Control Module (ECM) via CAN 2747
019 Counter of compressor switch-offs-Speed shut-off 5
020 Country coding Germany
021 Diagnostic mode VW - diagnostic mode
022 Dimmer signal-MUX Dimmungswert 0 %
023 Engine speed 600 /min
024 Engine start using start-stop function not active
025 Engine stop using start-stop function not active
026 Idle speed increase not active
027 Left heated seat stage 0
028 Number of prevented stop processes-Defrost active 0
029 Number of prevented stop processes-Maximum cooling selected 0
030 Number of prevented stop processes-Maximum heating selected 0
031 Number of prevented stop processes-Interior temperature difference to setting 0
032 Number of prevented stop processes-Interior vent difference to setting 0
033 Number of prevented stop processes-Manual fan speed increase 0
034 Number of prevented stop processes-Fogging hazard (calculated) 0
035 Number of prevented stop processes-Fogging hazard (humidity sensor) 0
036 Number of prevented stop processes-Interior comfort humidity too high (humidity sensor) 0
037 Number of requested start processes-Defrost active 0
038 Number of requested start processes-Maximum cooling selected 0
039 Number of requested start processes-Maximum heating selected 0
040 Number of requested start processes-Interior temperature difference to setting 0
041 Number of requested start processes-Interior vent difference to setting 0
042 Number of requested start processes-Manual fan speed increase 0
043 Number of requested start processes-Fogging hazard (calculated) 0
044 Number of requested start processes-Fogging hazard (humidity sensor) 0
045 Number of requested start processes-Interior comfort humidity too high (humidity sensor) 0
046 Number of unscheduled ECU resets 255
047 Outside air temperature-MUX Temperatur 25.0 °C
048 Outside air temperature internally calculated-MUX Temperatur 24.5 °C
049 Override of stop for air-conditioning settings Stop release
050 Prevented stop processes (ring memory) Measured value not available
051 Prevented stop processes (ring memory) 2063
052 Prevented stop processes (ring memory) 3
053 Prevented stop processes (ring memory) 31
054 Prevented stop processes (ring memory) 15
055 Prevented stop processes (ring memory) 3
056 Prevented stop processes (ring memory) 63
057 Recirculation flap specified value 0.0 %
058 Refrigerant pressure-MUX Kaeltemitteldruck 7.2 bar
059 Requested start processes (ring memory) Measured value not available
060 Requested start processes (ring memory) 2063
061 Requested start processes (ring memory) 3
062 Requested start processes (ring memory) 31
063 Requested start processes (ring memory) 15
064 Requested start processes (ring memory) 3
065 Requested start processes (ring memory) 63
066 Right heated seat stage 0
067 Start process requested Stop release
068 Start process requested System malfunction
069 Start-stop conditions Stop release
070 Start-stop enabling System malfunction
071 Start-stop function; coding information Start-stop function in control module not active
072 Status of input signals 11-Rear window heater actual value OFF
073 Status of input signals 11-Rear window heater target value OFF
074 Status of input signals 11-Auxiliary heater actual value OFF
075 Status of input signals 11-Auxiliary heater target value OFF
076 Status of input signals 11-Coolant temperature increase OFF
077 Status of input signals 11-Back-up light OFF
078 Status of input signals 11-Wiper OFF
079 Status of input signals 11-Actual value of windshield heater OFF
080 Status of input signals 11-Target value of windshield heater OFF
081 Status of input signals 11-Not assigned OFF
082 Status of recirculation air Recirculation due to pull down
083 Stop process prevented Stop release
084 Stop process prevented System malfunction
085 System run time-Engine running time 255 s
086 System run time-Terminal 15 on 255 s
087 Temperature after evaporator-MUX Temperatur nach Verdampfer 28.7 °C
088 Temperature flap; actual value 20
089 Temperature flap; cold stop 20
090 Temperature flap; specified value 0.0 %
091 Temperature flap; warm stop 224
092 Time since ignition off 8 min
093 Vehicle speed 0 km/h
094 Vehicle variant Sedan
095 Voltage terminal 30 13.8 V