** VCC = 3V ****
Voltage = 0.0V Error.
BDM out = 1, BDM in = 1 OK
RESET out = 1, Reset in = 1 OK
BDM out = 0, BDM in = 0. OK
RESET out = 0, RESET in = 0. OK
TX ---|<|---- BDM
TX = 1, BDM in = 1. OK
TX = 0, BDM in = 1. Error
BDM_RESET ---|<|---- RX
RESET = 1, RX in = 1. OK
RESET = 0, RX in = 1. Error
P0 ---|<|---- BDM
P0 = 1, BDM in = 1. OK
P0 = 0, BDM in = 1. Error
P1 ---|<|---- BDM
P1 = 1, BDM in = 1. OK
P1 = 0, BDM in = 1. Error
MBUS test
MBUS disabled.
TX = 0, RX = 1. OK
MBUS --|<|-- BDM Error
MBUS enabled.
TX = 0, RX = 0. OK
**** VCC = 5V ****
Voltage = 4.9V OK
BDM out = 1, BDM in = 1 OK
RESET out = 1, Reset in = 1 OK
BDM out = 0, BDM in = 0. OK
RESET out = 0, RESET in = 0. OK
TX ---|<|---- BDM
TX = 1, BDM in = 1. OK
TX = 0, BDM in = 1. Error
BDM_RESET ---|<|---- RX
RESET = 1, RX in = 1. OK
RESET = 0, RX in = 1. Error
P0 ---|<|---- BDM
P0 = 1, BDM in = 1. OK
P0 = 0, BDM in = 1. Error
P1 ---|<|---- BDM
P1 = 1, BDM in = 1. OK
P1 = 0, BDM in = 1. Error
MBUS test
MBUS disabled.
TX = 0, RX = 1. OK
MBUS --|<|-- BDM Error
MBUS enabled.
TX = 0, RX = 0. OK
10V = 10.2V OK
7.5V = 7.7V OK
Тест завершен.
|