Цитата:
как прошить?? |
У меня именно так, спасибо большое! буду копать в этом направлении )
|
удалял -ставил заново - все равно ставит теперь на диск С/софтинг.... что делать?
---------- вот лог :( ************ Getting MVCI Module paths ************* Root description file contains 1 MVCI modules. *********** Changing the PDU-API module ************ ---------------------------------------------------- Selected MVCI module: XS_D_PDU_API_OS ---------------------------------------------------- PDU-API dll: C:\ODIS-DIAG-MODULES\PDUAPI\VEN-IME\PDUAPI_I+ME_ACTIA_XS.dll PDU-API ModuleDescriptionFile: C:\ODIS-DIAG-MODULES\PDUAPI\VEN-IME\MDF_I+ME_ACTIA_XS.xml PDU-API CableDescriptionFile: C:\ODIS-DIAG-MODULES\PDUAPI\VEN-IME\CDF_I+ME_ACTIA_XS.xml Loading PDU-API library file... PduApiLibPath:"C:\ODIS-DIAG-MODULES\PDUAPI\VEN-IME\PDUAPI_I+ME_ACTIA_XS.dll" LoadLibrary Error:126 Error LoadLibrary(C:\ODIS-DIAG-MODULES\PDUAPI\VEN-IME\PDUAPI_I+ME_ACTIA_XS.dll). Trying LoadLibraryEx... LoadLibraryEx succeeded. Loading successful! ---------------------------------------------------- Parsing MDF file... MDF parser initialisation successful, MDF file loaded! MDF parsing completed! Fixing references completed! Warning: ComParam ID=3, value Overflow (Max or Min value is set) ! Warning: ComParam ID=33, value Overflow (Max or Min value is set) ! Warning: ComParam ID=34, value Overflow (Max or Min value is set) ! Warning: ComParam ID=36, value Overflow (Max or Min value is set) ! Warning: ComParam ID=86, value Overflow (Max or Min value is set) ! Warning: ComParam ID=89, value Overflow (Max or Min value is set) ! Warning: ComParam ID=91, value Overflow (Max or Min value is set) ! Warning: ComParam ID=128, value Overflow (Max or Min value is set) ! ---------------------------------------------------- Parsing CDF file... CDF parser initialisation successful, CDF file loaded! CDF parsing completed! ---------------------------------------------------- Return of PDUConstruct: PDU_STATUS_NOERROR: PDU function call successful ---------------------------------------------------- Return of PDUGetModuleIds: PDU_STATUS_NOERROR: PDU function call successful Error: No PduApi module found! |
Цитата:
Смотри какие строчки тебе доступны на выбор, если есть EDIC_D_PDU_API_1_20_23 то выбирай эту и смотри пути. Возможно будет строка EDIC_D_PDU_API_OE, она тоже от инжениринга но если она есть, и она нужной версии, то Сервис не ставит свой PDU_API а использует этот. поэтому выбирай её. Дальше смотри пути. По этим путям и найдешь заветную папку VAS5054. |
Цитата:
************ Getting MVCI Module paths ************* Root description file contains 3 MVCI modules. *********** Changing the PDU-API module ************ ---------------------------------------------------- Selected MVCI module: EDIC_D_PDU_API_OE ---------------------------------------------------- PDU-API dll: C:\Program Files (x86)\Softing\D-PDU API\1.20.023\vecom\PDUAPI_SoftingAG_1.20.023.dll PDU-API ModuleDescriptionFile: C:\Program Files (x86)\Softing\D-PDU API\1.20.023\vecom\MDF_SoftingAG_EDIC-PDU-API_1.20.023.xml PDU-API CableDescriptionFile: C:\Program Files (x86)\Softing\D-PDU API\1.20.023\vecom\CDF_SoftingAG_EDIC-PDU-API_1.20.023.xml Loading PDU-API library file... PduApiLibPath:"C:\Program Files (x86)\Softing\D-PDU API\1.20.023\vecom\PDUAPI_SoftingAG_1.20.023.dll" Loading successful! ---------------------------------------------------- Parsing MDF file... MDF parser initialisation successful, MDF file loaded! MDF parsing completed! Fixing references completed! Warning: ComParam ID=4, value Overflow (Max or Min value is set) ! Warning: ComParam ID=5, value Overflow (Max or Min value is set) ! Warning: ComParam ID=6, value Overflow (Max or Min value is set) ! Warning: ComParam ID=7, value Overflow (Max or Min value is set) ! Warning: ComParam ID=38, value Overflow (Max or Min value is set) ! Warning: ComParam ID=39, value Overflow (Max or Min value is set) ! Warning: ComParam ID=40, value Overflow (Max or Min value is set) ! Warning: ComParam ID=132, value Overflow (Max or Min value is set) ! Warning: ComParam ID=134, value Overflow (Max or Min value is set) ! ---------------------------------------------------- Parsing CDF file... CDF parser initialisation successful, CDF file loaded! CDF parsing completed! ---------------------------------------------------- Return of PDUConstruct: PDU_STATUS_NOERROR: PDU function call successful ---------------------------------------------------- Return of PDUGetModuleIds: PDU_STATUS_NOERROR: PDU function call successful ---------------------------------------------------- Number of modules found: 1 hMod: 1, ModuleStatus: PDU_MODST_AVAIL, Module Type ID: 531, Vendor Module Name: VendorName='Softing AG' ModuleName='VAS5054' SerialNumber='082145725', Vendor Additional Info: ConnectionType='USB' ---------------------------------------------------- Return of PDUModuleConnect: PDU_STATUS_NOERROR: PDU function call successful ************* Get module version Info ************** ---------------------------------------------------- Module Short Name : VendorName='Softing AG' ModuleName='VAS5054' SerialNumber='082145725' Module Vendor Name : Softing Automotive Electronics GmbH Module HwName : VAS5054 Module SerialNumber : 82145725 Module FW Name : VeCom Module FW-Version : 2.20.23 Module FW-Date : 8.9.2014 (Calendar week 36) Module PDU-API SW Name : Softing D-PDU API for VCIs Module PDU-API Version : 1.20.23 Module PDU-API SW Date : 8.9.2014 (Calendar week 36) ---------------------------------------------------- Return of PDUGetResourceIds: PDU_STATUS_NOERROR: PDU function call successful ---------------------------------------------------- Number of matching resource IDs: 1 ---------------------------------------------------- Selected resource ID: 81 ---------------------------------------------------- Return of PDUGetResourceIds: PDU_STATUS_NOERROR: PDU function call successful ---------------------------------------------------- Number of matching resource IDs: 1 ---------------------------------------------------- Selected resource ID: 81 |
Timur_ua,
По логу видно что что голова у Вас прошита 1.20.23 и нормально работает. Папку ВАС5054 подменять не нужно. Соединяйтесь с машиной и пробуйте. Но если приспичит, заменить можно по пути C:\Program Files (x86)\Softing\D-PDU API\1.20.023\vecom\ Там найдете папку VAS5054. |
спасибо, но не работает -пишет проверьте соединение или кабель :(
|
в админке у одиса нет в списке оборудования VAS5054 - как его туда добавить? я думаю в этом проблема.
|
Подскажите пожалуйста контакты где можно купить on-line доступ для полноценной работы проги.
PS На сайт официалов просьба не отсылать, я имел ввиду китайский проект. |
Вложений: 1
Подскажите у меня такой лог в тесте:
Машину ОДИС не видит(( |